Design Engineer - Memphis

Posted One Month Ago
Be an Early Applicant
Memphis, TN, USA
In-Office
Mid level
Information Technology
The Role
Design and support medium- and low-voltage electrical infrastructure for AI data centers. Responsibilities include creating electrical drawings, performing load and cable calculations, sizing transformers and switchgear, evaluating equipment specifications, supporting power-system studies, resolving construction RFIs, maintaining documentation, and ensuring compliance with electrical safety standards. The role is fully onsite in Memphis, includes hands-on construction and operations support, 24/7 emergency on-call duties, and travel of up to 25%.
Summary Generated by Built In

SpaceXAI’s mission is to create AI systems that can accurately understand the universe and aid humanity in its pursuit of knowledge. Our team is small, highly motivated, and focused on engineering excellence. This organization is for individuals who appreciate challenging themselves and thrive on curiosity. We operate with a flat organizational structure. All employees are expected to be hands-on and to contribute directly to the company’s mission. Leadership is given to those who show initiative and consistently deliver excellence. Work ethic and strong prioritization skills are important. All employees are expected to have strong communication skills. They should be able to concisely and accurately share knowledge with their teammates.

ABOUT THE ROLE:

Join the High Power Engineering team supporting SpaceXAI to design, build, operate, and maintain electrical infrastructure for AI training campuses. As a Design Engineer on the Data Center team, you will work with a small on-site team to scale high-capacity power systems on a schedule set by compute demand. The position is based in Memphis, TN, with potential travel to other sites.

RESPONSIBILITIES:
  • Produce and maintain single-line diagrams, three-lines, panel schedules, cable schedules, conduit and raceway layouts, grounding plans, and equipment elevations.
  • Perform load calculations, voltage drop, cable ampacity and derating, conduit fill, and pull-tension analysis including long underground runs.
  • Size MV/LV transformers, switchgear, busway, and feeders; specify impedance, BIL, temperature rise, and short-time ratings.
  • Write equipment specifications and technical bid evaluations for ring-main units, transformers, switchgear, busway, and PDUs.
  • Supply model inputs to protection and power-system studies: nameplate data, impedances, cable constants, and as-designed configurations.
  • Resolve field RFIs and issue design changes during construction.
  • Maintain organized design and asset documentation for Data Center electrical packages.
  • Ensure compliance with NFPA 70, 70B, 70E, NESC, and IEEE standards, prioritizing safety and engineering excellence.
BASIC QUALIFICATIONS:
  • Bachelor's degree in electrical engineering, computer engineering, physics, or another engineering discipline.
  • 3+ years of electrical design experience in data center, industrial, or utility facilities.
PREFERRED SKILLS AND EXPERIENCE:
  • Experience producing issued-for-construction drawing sets in AutoCAD, AutoCAD Electrical, or Revit.
  • Working knowledge of NEC Articles 110, 215, 240, 250, 310, and 450.
  • Medium-voltage cable system design experience.
  • Experience with power systems analysis software and tools: ETAP, SKM, EasyPower, Matlab, PSCAD, etc.
  • Revit or BIM coordination experience.
  • Engineer in Training certification, or on track for a Professional Engineer license.
  • Experience on a repeated, multi-phase build rather than one-off projects.
  • Demonstrated initiative, creative problem-solving, and strong analytical/engineering fundamentals.
ADDITIONAL REQUIREMENTS
  • Perform hands-on work in all environments (heat, cold, rain), in tight quarters or at heights.
  • Work extended hours and weekends as needed to support construction, energization, and operations.
  • Remain focused in hazardous environments while wearing appropriate PPE.
  • Lift up to 25 lbs. unassisted.
  • Provide 24/7 on-call support for emergencies.
  • Willing to work on-site in Memphis, TN. This is not a remote or hybrid role.
  • Travel up to 25% for factory witness testing, vendor and OEM engagement, and supporting other sites.
  • Valid driver's license.

SpaceXAI is an equal opportunity employer. For details on data processing, view our Recruitment Privacy Notice.

Skills Required

  • Bachelor's degree in electrical engineering, computer engineering, physics, or another engineering discipline
  • 3+ years of electrical design experience in data center, industrial, or utility facilities
  • Experience producing issued-for-construction drawing sets using AutoCAD, AutoCAD Electrical, or Revit
  • Working knowledge of NEC Articles 110, 215, 240, 250, 310, and 450
  • Medium-voltage cable system design experience
  • Experience with power systems analysis software such as ETAP, SKM, EasyPower, MATLAB, or PSCAD
  • Revit or BIM coordination experience
  • Engineer in Training certification or progress toward a Professional Engineer license
  • Experience with repeated, multi-phase builds
  • Strong analytical and engineering fundamentals, initiative, and creative problem-solving
  • Ability to work onsite in Memphis, Tennessee
  • Valid driver's license
  • Ability to work in hazardous environments, tight quarters, at heights, and varying weather conditions
  • Ability to lift up to 25 pounds unassisted
  • Availability for extended hours, weekends, and 24/7 emergency on-call support
Am I A Good Fit?
beta
Get Personalized Job Insights.
Our AI-powered fit analysis compares your resume with a job listing so you know if your skills & experience align.

The Company
HQ: Palo Alto, CA
96 Employees

What We Do

Understand the Universe

Similar Jobs

Samsara Logo Samsara

Staff Software Engineer

Artificial Intelligence • Cloud • Computer Vision • Hardware • Internet of Things • Software
Easy Apply
Remote or Hybrid
United States
4000 Employees
162K-290K Annually

NinjaOne Logo NinjaOne

Enterprise Architect

Information Technology • Productivity • Software • Infrastructure as a Service (IaaS)
Remote or Hybrid
12 Locations
2000 Employees
150K-170K Annually

January Logo January

Recovery Specialist

Artificial Intelligence • Fintech • Payments • Social Impact • Analytics • Financial Services • Automation
Remote or Hybrid
USA
111 Employees
56K-60K Annually

BECU Logo BECU

Manager Procurement Operations

Fintech • Financial Services
Remote or Hybrid
3 Locations
3000 Employees
102K-189K Annually

Similar Companies Hiring

Axle Health Thumbnail
Artificial Intelligence • Healthtech • Information Technology • Logistics
Santa Monica, CA
25 Employees
NODA AI Thumbnail
Artificial Intelligence • Information Technology • Software • Cybersecurity
Sydney, AU
54 Employees
Golden Pet Brands Thumbnail
Digital Media • eCommerce • Information Technology • Marketing Tech • Pet • Retail • Social Media
El Segundo, California
178 Employees

Sign up now Access later

Create Free Account

Please log in or sign up to report this job.

Create Free Account