Power Systems Engineer

Posted 4 Days Ago
Be an Early Applicant
Centennial, CO, USA
In-Office
107K-187K Annually
Mid level
Aerospace • Travel • Manufacturing
The future is Supersonic.
The Role
Lead end-to-end design, protection, and commissioning of a standalone 13.8kV medium-voltage system for a 42MW turbine platform. Responsibilities include MV architecture, one-line diagrams, relay coordination and settings, breaker and switchgear specification, generator excitation and synchronization, fault current and interrupting-duty analysis, CT/PT selection, load-bank testing, neutral grounding strategy, arc-flash analysis, and field commissioning.
Summary Generated by Built In


Tame 42 megawatts at 13.8kV, protect it, control it, and deliver it through a power architecture built to scale to gigawatts for next-generation AI data centers.


Boom Supersonic is building Superpower — a 42-megawatt industrial gas turbine derived from supersonic propulsion technology, purpose-built for frontier AI data centers where power demand is scaling faster than the grid can keep up. This role owns the medium-voltage system that turns shaft power into dependable 13.8kV electrical power, carrying it from generator terminals to islanded load while ensuring the system can protect itself, stay online, and deliver power when it matters.


This is medium-voltage electrical engineering at industrial scale.

The Superpower platform is designed to operate in arrays that scale to gigawatt-class islanded power. There is no grid to lean on for frequency reference, fault current, or voltage stability. You're not designing a system that parallels an infinite bus and lets the grid handle the hard problems. You're defining from first principles how a standalone 13.8kV machine starts, regulates voltage and frequency, rides through transients, protects itself under fault conditions, and delivers reliable power to critical loads. Grid interconnect is an option for certain applications — but off-grid is the primary design condition, and the harder one.


There's no existing system to reference and no legacy protection scheme to copy. This is the kind of role where that's the point — and we're looking for an engineer who finds genuine energy in the parts of the job nobody has done before.


What You'll Own

You'll lead the end-to-end electrical design of the 13.8kV medium-voltage system on Superpower — from architecture through first energization, endurance testing, and field commissioning. That means being in the room (and on the test floor) for all of it, with real influence over the outcome at every stage.


In practice, that means:

  • Defining the MV architecture, single-line diagrams, protection philosophy, and concept of operations during preliminary design, including long-lead switchgear and generator circuit breaker specification and sourcing.
  • Producing protection coordination studies, relay settings, and MV electrical drawings through detailed design.
  • Leading first energization, relay commissioning, synchronization, load acceptance, and step-load testing.


The 13.8kV electrical system is yours, end-to-end:

  • Generation, distribution, and protection of all medium-voltage power, from 13.8kV generator terminals through switchgear to downstream loads and optional grid interconnect.
  • Generator excitation, voltage regulation, and interface requirements with the turbine control system.
  • Switchgear and breaker systems, including generator circuit breakers, feeder breakers, and bus-tie configurations.
  • Protection relay selection, settings, and coordination — differential, overcurrent, ground fault, voltage, and frequency protection.
  • Fault-current management, interrupting-duty analysis, and equipment rating coordination.
  • Frequency control, synchronization, and load acceptance for islanded operation.
  • CT/PT selection, metering, and sensing infrastructure for protection, control, and monitoring.
  • MV load bank integration, transient response, and step-load testing.
  • Neutral grounding strategy and ground fault detection.
  • Arc-flash hazard analysis, electrical safety systems, and interlock design.


You probably have:

  • Deep hands-on experience with medium-voltage systems — switchgear, breakers, protective relaying, grounding, and generator integration in industrial or power-generation environments.
  • A solid understanding of rotating machinery: generator behavior, excitation, AVR systems, synchronization, and transient response under load, faults, and trips.
  • Experience with protection coordination — relay selection, settings, differential and overcurrent schemes — and the ability to own that work from study through commissioning.
  • The ability to read and produce clean MV electrical drawings (one-lines, wire diagrams, panel layouts) that can be built and commissioned without ambiguity.
  • Comfort working across mechanical, controls, and instrumentation teams and translating between them when needed.


You will thrive here if:

  • You have a clear point of view on how medium-voltage systems should be built, and you'd rather voice it early than quietly inherit someone else's assumptions.
  • First energization day is exciting to you, not just stressful — and when something doesn't work, you're the one who wants to be tracing it.
  • You're as comfortable on a switchgear lineup as you are at a desk producing coordination studies.
  • You want to be the reason the system works — not just a contributor to the process that produced it.


Compensation

  • P2 Level - Typically 0 - 4 years of experience - Base salary range: $107,000 - $144,000
  • P3 Level — Typically 5–10 years of experience — Base salary range: $124,800 - $167,700
  • P4 Level — Typically 10–15 years of experience — Base salary range: $139,200 - $187,050


Actual salaries will vary based on factors including but not limited to location, experience, and performance. The range listed is just one component of Boom's total rewards package for employees. Other rewards may include long-term incentives/equity, a flexible PTO policy, and many other progressive benefits.


There is no set deadline to apply for this job opportunity. Applications will be accepted on an ongoing basis until the search is no longer active.


ITAR Requirement

To conform to U.S. Government aerospace technology export regulations (ITAR and EAR), applicants must be a U.S. citizen, lawful permanent resident of the U.S., protected individual as defined by 8 U.S.C 1324b(a)(3), or eligible to obtain the required authorizations from the U.S. Department of State. Learn more about ITAR here.


Boom is an equal opportunity employer and we value diversity. All employment is decided on the basis of qualifications, merit, and business need.


Want to build a faster future? Come join Boom.


Skills Required

  • Hands-on experience with medium-voltage systems (switchgear, breakers, protective relaying, grounding, generator integration)
  • Solid understanding of rotating machinery, generator behavior, excitation systems, AVR, synchronization, and transient response
  • Experience performing protection coordination studies, relay selection, settings, differential and overcurrent schemes, and commissioning relays
  • Ability to produce and read MV electrical drawings (one-lines, wiring diagrams, panel layouts) suitable for construction and commissioning
  • Experience leading first energization, relay commissioning, synchronization, load acceptance, and step-load testing
  • Knowledge of CT/PT selection, metering, sensing infrastructure, and fault-current/interrupting-duty analysis
  • Experience with neutral grounding strategies, ground fault detection, arc-flash hazard analysis, electrical safety systems, and interlocks
  • Ability to work cross-functionally with mechanical, controls, and instrumentation teams
  • Authorization/eligibility under ITAR (U.S. citizen, lawful permanent resident, protected individual, or eligible for required authorizations)
Am I A Good Fit?
beta
Get Personalized Job Insights.
Our AI-powered fit analysis compares your resume with a job listing so you know if your skills & experience align.

The Company
HQ: Centennial, CO
148 Employees
Year Founded: 2014

What We Do

Boom Supersonic is the Denver-based startup bringing supersonic flight back to the skies with Overture. As the world’s fastest airliner, Overture is designed and committed to industry-leading standards of speed, safety and sustainability. Flights twice as fast as today’s commercial airplanes, means we can go twice as far.

Why Work With Us

Boom is the first commercial airplane manufacturer to commit to a carbon-neutral flight test program and to build sustainability into its entire aircraft program. Founded in 2014, Boom has assembled a team of over 240 full-time employees who have made contributions to over 220 air and spacecraft programs.

Gallery

Gallery

Similar Jobs

True Anomaly Logo True Anomaly

Electrical Engineer

Aerospace • Artificial Intelligence • Hardware • Machine Learning • Software • Defense • Manufacturing
In-Office
2 Locations
300 Employees
135K-250K Annually

True Anomaly Logo True Anomaly

Electrical Engineer

Aerospace • Artificial Intelligence • Hardware • Machine Learning • Software • Defense • Manufacturing
In-Office
2 Locations
300 Employees
90K-135K Annually

BAE Systems, Inc. Logo BAE Systems, Inc.

Principal Engineer

Aerospace • Hardware • Information Technology • Security • Software • Cybersecurity • Defense
Hybrid
Boulder, CO, USA
40000 Employees
150K-254K Annually

BAE Systems, Inc. Logo BAE Systems, Inc.

Principal Engineer

Aerospace • Hardware • Information Technology • Security • Software • Cybersecurity • Defense
Hybrid
Boulder, CO, USA
40000 Employees
133K-226K Annually

Similar Companies Hiring

Rosendin Thumbnail
Other • Manufacturing
San Jose, CA
6219 Employees
Amalgamated Sugar Thumbnail
Food • Greentech • Agriculture • Industrial • Manufacturing
Boise, Idaho
768 Employees
Outpost Space Thumbnail
Aerospace • Defense
US
24 Employees

Sign up now Access later

Create Free Account

Please log in or sign up to report this job.

Create Free Account